hohner |
Hohner Automation Ltd. |
Home | Distributors | Terms | About Us | Accessories | Download 3D AutoCAD |
Series 08 incremental stainless steel encoder up to 1/2" |
|
0 | 8 | X | X | - | 1 | 3 | X | S | - | X | X | X | X | |||||||||||
Shaft Size |
Connection |
| |
|
Resolution - ppr |
|||||||||||||||||||||
Hollow Shaft | 1 = 2 m cable | | | |||||||||||||||||||||||
A4 = 3/8 " | 2 = 5 m cable | | | |||||||||||||||||||||||
A5 = 1/2 " | | | ||||||||||||||||||||||||
08 = 8 mm | Housing | ||||||||||||||||||||||||
10 = 10 mm |
S = Stainless Steel |
||||||||||||||||||||||||
12 = 12 mm | |||||||||||||||||||||||||
5...24 Volt Extended Line Driver is standard, optional Current Sink Open Collector is available
Zone 0, Class 1 Div 1 |
Technical Data | Connection Options | |||||
Operating temp: | - 20 ...+ 60 degrees C | 9 pole | Cable | |||
- 4 ...+ 140 degrees F | PS GND | 1 | Black | |||
Max frequency: | 100 kHz | PS 5 ... 24 V | 2 | Red | ||
Current consumption: | 50 mA (max.) | Output A | 3 | White | ||
Power supply: | 5 - 24V | Output B | 4 | Blue | ||
Weight: | 23 oz (0.75 kg) | Output O | 5 | Yellow | ||
Protection: | IP 66 /X7 M | Output A inv | 6 | Green | ||
(1m depth for 1 hour on IP67M) | Output B inv | 7 | Violet | |||
Housing: | Stainless Steel | Output O inv | 8 | Brown | ||
Shaft: | Stainless Steel | |||||
Bearings: | 3 x 6803 ZZ C2 | Output | ||||
Torque: | 0.4 oz/in (3 N-cm) | Diagram is shown with clockwise shaft rotation viewed from | ||||
Humidity: | Up to 98% permissible |
grub screw side |
||||
Speed: | 3000 RPM max. |
![]() |
||||
Shock: | 10g (6msec) | |||||
Vibration: | 5g (500 Hz) | |||||
Shaft load: | Radial / axial max 10 lbs | |||||
Line driver output max: | 50 mA per channel | |||||
Max. ppr | 1500 | |||||
Inertia: | 30 gm-cm2 |
Certifications |
To use the encoder in a hazardous area, a safety barrier or galvanic isolator has to be used. Our six channel barrier and isolator work with our encoders. Isolator Data Sheet |
IP 67M |
ATEX [Certificate] |
IECEx [Certificate] |
CSA [Certificate] |
GOST-CU [Certificate] |
Mounting Instructions |
Mount the tether on the machine or motor-frame. The tether can be bent to adapt to any surface. This assembly allows the encoder to float and increases the lifetime of the bearings. Connect the encoder as per wiring specifications. Make sure power supply is within the proper voltage and current rating. Encoder can be mounted with the setscrew on the machine side or on the opposite side for either CW or CCW. See datasheet for CW and CCW directions of the outputs.
Technical data for tether: 0.3 mm stainless steel sheet
|
Dimensions |
|
Hohner Automation Ltd. | Tel: +44 (0) 1978 363-888 |
Whitegate Industrial Estate | Fax: +44 (0) 1978 364-586 |
Wrexham LL13 8UG | E-mail: uksales@hohner.com |
United Kingdom | Web: www.hohneronline.co.uk |