hohner

    Hohner Automation Ltd.


Home Email Distributors Terms About Us Accessories Download 3D AutoCAD

Series MXE stainless steel shaft encoder (Ex d) up to 12 mm


M   E X X - 1 3 X X - X X X X
 

|

 

Shaft Size

|  

|

    

Resolution - ppr

| K5 = 12 x 20 mm | Exit
| | A = Axial

| | R = Radial
Protection

|

E = IP66/67 Stainless Steel Connection
3 = 10m cable
5 = 20m cable
  

5...24 Volt Extended Line Driver is standard, optional Current Sink Open Collector is available

    IECEx

Class I, Zone 1; Zone 21;  Class II, Div 2


Technical Data Connection Options
Operating temp: - 20 ...+   60 degrees C Cable
-   4 ...+ 140 degrees F PS GND Black
PS 5 ... 24 V Red
Max frequency: 150 kHz Output A White
Current consumption: 80 mA (max.) Output B Blue
Power supply: 5 - 24V Output O Yellow
Weight: 2.5Kg Output A inv Green
Protection: IP 66/67 Output B inv Violet
Housing: S. Steel Output O inv Brown
Shaft: S. Steel
Bearings: 2 x 6001 RSH Output
Torque: 0.7 oz/in (5 N-cm) Diagram is shown with clockwise shaft rotation viewed from 
Humidity: Up to 98% permissible

shaft end

Speed:  6000 RPM max.
Shock: 10g (6msec)
Vibration: 5g (500 Hz)
Shaft load: Radial / Axial 10 N
Line driver output max: 50 mA per channel
Max. ppr 5000
Inertia: 100 gm-cm2

Certifications
Flameproof, does not require barrier for use in hazardous areas, and we use a barrier gland for added safety
IP 66/X7
ATEX [Certificate]
IECEx [Certificate]
CSA [Certificate]
GOST-CU [Certificate]
 
Mounting Instructions
Hook up the encoder with the connections as described.  Make sure power supply meets specifications.  Attach encoder to mounting bracket as shown.  Attach shaft using a flexible coupling.

Dimensions


Hohner Automation Ltd. Tel: +44 (0) 1978 363-888
Whitegate Industrial Estate Fax: +44 (0) 1978 364-586
Wrexham LL13 8UG E-mail: uksales@hohner.com
United Kingdom Web: www.hohneronline.co.uk